<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://bone.wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bryn.Matheson</id>
	<title>bone.wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://bone.wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Bryn.Matheson"/>
	<link rel="alternate" type="text/html" href="https://bone.wiki/index.php/Special:Contributions/Bryn.Matheson"/>
	<updated>2026-10-29T07:39:36Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.46.2</generator>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7479</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7479"/>
		<updated>2025-05-01T21:53:14Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Asynchronous calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners during quantitative analysis derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen here: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
To run phantom calibration in Ogo, you will need two things: &lt;br /&gt;
&amp;lt;ol&amp;gt; &lt;br /&gt;
  &amp;lt;li&amp;gt;The raw CT scan (.nii or .nii.gz)&amp;lt;/li&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;A segmentation mask of the phantom rods&amp;lt;/li&amp;gt; &lt;br /&gt;
&amp;lt;/ol&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects.&lt;br /&gt;
&lt;br /&gt;
An example of the phantom rods segmented: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_seg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away. (This is an ongoing edited section...)&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7463</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7463"/>
		<updated>2025-03-07T22:45:17Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners during quantitative analysis derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen here: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
To run phantom calibration in Ogo, you will need two things: &lt;br /&gt;
&amp;lt;ol&amp;gt; &lt;br /&gt;
  &amp;lt;li&amp;gt;The raw CT scan (.nii or .nii.gz)&amp;lt;/li&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;A segmentation mask of the phantom rods&amp;lt;/li&amp;gt; &lt;br /&gt;
&amp;lt;/ol&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects.&lt;br /&gt;
&lt;br /&gt;
An example of the phantom rods segmented: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_seg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7462</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7462"/>
		<updated>2025-03-07T22:35:15Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Phantom calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen here: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
To run phantom calibration in Ogo, you will need two things: &lt;br /&gt;
&amp;lt;ol&amp;gt; &lt;br /&gt;
  &amp;lt;li&amp;gt;The raw CT scan (.nii or .nii.gz)&amp;lt;/li&amp;gt;&lt;br /&gt;
&amp;lt;li&amp;gt;A segmentation mask of the phantom rods&amp;lt;/li&amp;gt; &lt;br /&gt;
&amp;lt;/ol&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects.&lt;br /&gt;
&lt;br /&gt;
An example of the phantom rods segmented: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_seg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7461</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7461"/>
		<updated>2025-03-07T22:32:44Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen here: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
To run phantom calibration in Ogo, you will need two things: &lt;br /&gt;
 1. The raw CT scan (.nii or .nii.gz) &lt;br /&gt;
 2. A segmentation mask of the phantom rods. Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of &lt;br /&gt;
 the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects.&lt;br /&gt;
&lt;br /&gt;
An example of the phantom rods segmented: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_seg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7460</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7460"/>
		<updated>2025-03-07T22:31:01Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Phantom calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen here: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
To run phantom calibration in Ogo, you will need two things: &lt;br /&gt;
1. The raw CT scan (.nii or .nii.gz) &lt;br /&gt;
2. A segmentation mask of the phantom rods. Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects.&lt;br /&gt;
&lt;br /&gt;
An example of the phantom rods segmented: &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_seg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7459</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7459"/>
		<updated>2025-03-07T22:27:43Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Phantom calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen below. &lt;br /&gt;
&lt;br /&gt;
[[Image:phantom_rods_noseg.png|600px]]&lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=File:Phantom_rods_seg.png&amp;diff=7458</id>
		<title>File:Phantom rods seg.png</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=File:Phantom_rods_seg.png&amp;diff=7458"/>
		<updated>2025-03-07T22:24:58Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: Example of phantom calibration with segmentation overlayed&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Example of phantom calibration with segmentation overlayed&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=File:Phantom_rods_noseg.png&amp;diff=7457</id>
		<title>File:Phantom rods noseg.png</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=File:Phantom_rods_noseg.png&amp;diff=7457"/>
		<updated>2025-03-07T22:24:25Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: Example of phantom calibration&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Example of phantom calibration&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7456</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7456"/>
		<updated>2025-03-07T22:07:58Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen below. &lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7455</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7455"/>
		<updated>2025-03-07T22:07:46Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
To ensure accurate material properties and comparability across clinical sites and scanners for quantitative analysis of bone derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. &lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen below. &lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7454</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7454"/>
		<updated>2025-03-07T22:06:08Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Phantom calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting Hounsfield Units (HUs) to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; under the patient in the scan field of view, as seen below. &lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2&amp;lt;/sub&amp;gt;HPO&amp;lt;sub&amp;gt;4&amp;lt;/sub&amp;gt; found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7453</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7453"/>
		<updated>2025-03-07T22:04:59Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Phantom calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
Phantom calibration is the current imaging gold standard for converting Hounsfield Units (HUs) to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K&amp;lt;sub&amp;gt;2HPO&amp;lt;sub&amp;gt;4under the patient in the scan field of view, as seen below. &lt;br /&gt;
&lt;br /&gt;
The solid CHA or liquid  K&amp;lt;sub&amp;gt;2HPO&amp;lt;sub&amp;gt;4 found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). &lt;br /&gt;
&lt;br /&gt;
The calibration curve takes the form of&lt;br /&gt;
 BMD = (HU⋅a) + b&lt;br /&gt;
&lt;br /&gt;
where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and b  depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. &lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7452</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7452"/>
		<updated>2025-03-03T17:12:57Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Asynchronous calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
This uses a phantom.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7451</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7451"/>
		<updated>2025-03-03T17:12:46Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Asynchronous calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
This uses a phantom.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the &amp;lt;code&amp;gt;same&amp;lt;/code&amp;gt; time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7450</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7450"/>
		<updated>2025-03-03T17:12:02Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Asynchronous calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
This uses a phantom.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the &amp;lt;code&amp;gt;same&amp;lt;/code&amp;gt; time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
y = mx + b&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 A = B&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7449</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7449"/>
		<updated>2025-03-03T17:11:09Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Asynchronous calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
This uses a phantom.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
y = mx + b&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
 A = B&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
	<entry>
		<id>https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7448</id>
		<title>Opportunistic CT</title>
		<link rel="alternate" type="text/html" href="https://bone.wiki/index.php?title=Opportunistic_CT&amp;diff=7448"/>
		<updated>2025-03-03T17:10:39Z</updated>

		<summary type="html">&lt;p&gt;Bryn.Matheson: /* Calibration */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Radiation Dose=&lt;br /&gt;
&lt;br /&gt;
X-rays are a form of energy – like light and radio waves. X-rays are also called radiation. Unlike light waves, x-rays have enough energy to pass through your body. As the radiation moves through your body, it passes through bones, tissues, and organs differently. This allows a radiologist to create images of them. The radiologist is a specially trained doctor who can examine these images on a computer display. X-rays allow the radiologist to see the structures in your body in very fine detail.&lt;br /&gt;
&lt;br /&gt;
==Dose Length Product==&lt;br /&gt;
&lt;br /&gt;
Dose length product (DLP) is a measure of CT tube radiation output/exposure (measured in mGy.cm). It is related to volume CT dose index (CTDIvol), but CTDIvol represents the dose through a slice of an appropriate phantom. The dose length product accounts for the length of radiation output along the z-axis (the long axis of the patient). It may be described by the following equation:&lt;br /&gt;
&lt;br /&gt;
 DLP = (CTDIvol in mGy) . (length of scan in cm)&lt;br /&gt;
&lt;br /&gt;
The dose length product does not take the size of the patient into account and is not a measure of absorbed dose. If the AP and lateral dimensions of the patient are available, then the size specific dose estimate (SSDE) can be used to estimate the absorbed dose.&lt;br /&gt;
&lt;br /&gt;
==Effective Dose==&lt;br /&gt;
&lt;br /&gt;
Some estimates of effective dose are summarized in the table below, taken from the cited sources.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot; &lt;br /&gt;
|+ Estimates of Effective Dose&amp;lt;sup&amp;gt;1,2,3&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
! Scan !! Effective Dose (mSv)&lt;br /&gt;
|-&lt;br /&gt;
| Head || 2.2&lt;br /&gt;
|-&lt;br /&gt;
| Full Spine || 20.6&lt;br /&gt;
|-&lt;br /&gt;
| Cervical || 3.6&lt;br /&gt;
|-&lt;br /&gt;
| Thoracic || 12.0&lt;br /&gt;
|-&lt;br /&gt;
| Lumbar || 5.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest || 6.0&lt;br /&gt;
|-&lt;br /&gt;
| Chest/Abdo/Pelvis || 19.0&lt;br /&gt;
|-&lt;br /&gt;
| Abdo/Pelvis || 15.6&lt;br /&gt;
|-&lt;br /&gt;
| Knees || 0.16&lt;br /&gt;
|-&lt;br /&gt;
| Ankles || 0.14&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;1&amp;lt;/sup&amp;gt;Conference of Radiation Control Program Directors (CRCPD) Nationwide Evaluation of X-ray Trends (NEXT) 2005-2006 [https://crcpd.org/document/nationwide-evaluation-of-x-ray-trends-next-tabulation-and-graphical-summary-of-the-2005-2006-survey-of-computed-tomography/ report]. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;CRCPD, Publication E-07-2, Tabulation and Graphical Summary of 2000 Survey of Computed Tomograph, (NEXT), August, 2007&lt;br /&gt;
&lt;br /&gt;
&amp;lt;sup&amp;gt;3&amp;lt;/sup&amp;gt;Biswas et al. Radiation Exposure from Musculoskeletal Computerized Tomographic Scans. The Journal of Bone and Joint Surgery, 2009. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;b&amp;gt;Notes:&amp;lt;/b&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Full Spine&amp;lt;/b&amp;gt;: From the base of the skull (C1) to the sacrum (through L5), effective dose of 20.6 mSv (adding up dose of all spine scans)&lt;br /&gt;
&lt;br /&gt;
*&amp;lt;b&amp;gt;Extended Chest/Abdo/Pelvis&amp;lt;/b&amp;gt; (or Full Spine + Abdo/Pelvis): From the base of the skull (C1) through the proximal femur. Effective dose of 25.2 mSv (cervical spine + chest + abdo/pelvis). Likely this is an overestimation. &lt;br /&gt;
&lt;br /&gt;
Dose Length Product (DLP) of ARTININ scans is usually between 270 – 400 mGy-cm. &lt;br /&gt;
&lt;br /&gt;
Converting between mGy-cm to effective dose (as described by the American Association of Physicists in Medicine (AAPM) Report No. 96): &lt;br /&gt;
 E (mSv) = k × DLP&lt;br /&gt;
where &amp;lt;code&amp;gt;k&amp;lt;/code&amp;gt; is the normalized effective dose per dose-length product for adults.&lt;br /&gt;
&lt;br /&gt;
Estimated effective dose for ARTININ (as according to DLP): &lt;br /&gt;
 E (mSv) = 0.015 × 400 &lt;br /&gt;
 E (mSv) = 6 mSv&lt;br /&gt;
&lt;br /&gt;
Note that in the ARTININ consent we list 10 mSv, which is on the high end (which would be for a larger person).&lt;br /&gt;
&lt;br /&gt;
Full spine (estimates of DLP taken from a few participants in the spinal cord injury group): 705 - 958. 55m mGy-cm &lt;br /&gt;
&lt;br /&gt;
Note that DLP is over twice what is observed in ARTININ &lt;br /&gt;
 E (mSv) = 0.015 × 958.55 &lt;br /&gt;
 E (mSv) = 14.5 mSv&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
==Calibration==&lt;br /&gt;
&lt;br /&gt;
There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo].&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Phantom calibration===&lt;br /&gt;
&lt;br /&gt;
This uses a phantom.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Asynchronous calibration===&lt;br /&gt;
&lt;br /&gt;
This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
y = mx + b&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;br /&gt;
&lt;br /&gt;
===Internal calibration===&lt;br /&gt;
&lt;br /&gt;
This doesn&#039;t use a phantom, but instead uses the internal tissues as referents.&lt;br /&gt;
&lt;br /&gt;
[[Image:Redirect.jpg|15px]] [[#top|&#039;&#039;Return to Contents&#039;&#039;]] or [[Main_Page|&#039;&#039;Return to Main Page&#039;&#039;]]&lt;/div&gt;</summary>
		<author><name>Bryn.Matheson</name></author>
	</entry>
</feed>