====Update a scan with new calibration or BHC==== If the QC1 range was out of range but it was not possible to update the system calibration before scanning, you can update the scan with the new density calibration (i.e., slope and intercept). It is also possible to change the beam hardening correction that is applied (e.g., from 200 mg HA/cm3 to 1200 mg HA/cm3). {| class="wikitable" |- ! scope="col"| Type of Update ||RSQ||ISQ||AIM |- |QC1 was out of range, need new slope and intercept (e.g., after updating the system calibration) |Yes||Yes||No, Create New |- |Change beam hardening correction type (e.g., 200 mg HA/cm3 to 1200 mg HA/cm3) |Yes||No, Reconstruct||No, Create New |} Use the UCT_EXT_HEADER_ADD_CALIB program to update an RSQ and, if appropriate, repeat for the ISQ. *Use default values for all prompts except those commented after !. <pre> $ mcr ut:uct_ext_header_add_calib UCT_EXT_HEADER_ADD_CALIB V 1.1 Raw-Data-File []: !give the name of the RSQ/ISQ with full path if not in that directory Reading Raw Data ... IDX Calib Description 1 1 45 kVp, 200mg HA wedge, 4096 scaling 2 2 55 kVp, 200mg HA wedge, 4096 scaling 3 3 70 kVp, 200mg HA wedge, 4096 scaling 4 4 General, non-bone-density-calibrated scan, scale 4096 5 5 45 kVp, BH: 1200 mg HA/ccm, Scaling 4096 6 6 55 kVp, BH: 1200 mg HA/ccm, Scaling 4096 7 7 70 kVp, BH: 1200 mg HA/ccm, Scaling 4096 Calibration Record No [0]: !specify the new calibration, e.g. 6 Calibration No. 6 Description 55 kVp, BH: 1200 mg HA/ccm, Scaling 4096 Scanner-ID 5019 Energy [V] 55000 Antiring Enable 0 Beamhardening Enable 1 Beamhardening Coeff file UCTD:UCT_BH_COEFF_55KV_1200HA_5019.TXT Default unit type (1=Β΅, 2=mg, 3=HU, 4=Custom) 2 Same type already found. Setting old to invalid SUCCESS: calib hext written updating header... SUCCESS: Header successfully updated. Calib record indicates that BH-Corr is usually applied. Info: There is a BH-Corr corr already in hext. Add another BH-Corr from file again? (Y/N) [N]: Y </pre> [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']]
Summary:
Please note that all contributions to bone.wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BoneWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Log in
associated-pages
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main page
Documents
Recent changes
Help
Tools
What links here
Related changes
Page information