Editing
Scanco Administration
(section)
Jump to navigation
Jump to search
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Image Artifacts== ===Ring Artifact=== *Refer to [[Media:Microct_ring_correction.pdf|'''MicroCT Ring Correction''']]. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ===Partial Volume Effect=== *Refer to [[Media:Partial_Volume_Effect.pdf|'''Partial Volume Effect''']]. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ===Beam Hardening Correction (BHC)=== ====Use the right BHC==== *Refer to [[Media:Beam_hardening_correction.pdf|'''Use the right beam hardening correction''']]. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ====Understand Scanco BHC==== If you see lines like 'CCD_CORR: Expand BH-corr to1536' etc. etc.: then we do a polynomial correction: <pre> $ dir uctd:*bh_coeff*.txt </pre> and you see a file with the scanner ID. <pre> --> $ type uctd:UCT_BH_COEFF_60KV_0200HA_3309.TXT --> ! Function 9 is Addpolynom Function: 9 A 0: 3 0.00000000 -0.38599902 0.30870225 -0.06162301 --> 0: for all pixels. 3 --> 3rd degree polynom, with factors: x^0 = 0 x^1 = -0.38... x^2 = 0.308... x^3 = -0.061... </pre> This polynom is added to the PROJECTION value (not the raw counts). the BH-corr is doing a 'linearization', e.g. see http://iospress.metapress.com/content/twcxb9jfk8knhpq2/ for more info. The values in the middle of the scan are amplified more - not just because of their position, but because the object is thicker there, thus the projection values are higher, thus the correction term is higher. <b>NOTE</b> : Linearisation, as used by Scanco, will compensate 'soft-tissue' beam hardening (inside of water phantom appears <b>LESS</b> dense). Bone related beam hardening, e.g. soft tissue near skull appearing <b>MORE</b> dense, will <b>NOT</b> generally be compensated. See Kak and Slaney 'Principles of computerized tomogprahic imaging' and Joseph and Spital J Comp Assist Tomo 1978 vol 2 for more information. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']]
Summary:
Please note that all contributions to bone.wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BoneWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Log in
associated-pages
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main page
Documents
Recent changes
Help
Tools
What links here
Related changes
Page information