==Calibration== To ensure accurate material properties and comparability across clinical sites and scanners during quantitative analysis derived from clinical CT scans, the native in-scan Hounsfield Units (HUs) must be converted to their corresponding bone equivalent densities. There are three main types of calibration for CT scans. All of these methods are available in our GitHub repository called [https://github.com/Bonelab/Ogo Ogo]. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ===Phantom calibration=== Phantom calibration is the current imaging gold standard for converting HUs to bone densities. Phantom calibration involves placing a calibration phantom with known density values of either solid CHA or liquid K<sub>2</sub>HPO<sub>4</sub> under the patient in the scan field of view, as seen here: [[Image:phantom_rods_noseg.png|600px]] The solid CHA or liquid K<sub>2</sub>HPO<sub>4</sub> found in the phantom acts as the bone equivalent reference standard. Phantom calibration requires sampling the in-scan HUs of the bone equivalent reference rods (from the calibration phantom) and comparing those values to the known reference values. A simple linear regression between the known values within the calibration phantom rods and the in-scan HUs can be created to convert the HUs to bone equivalent density (BMD). The calibration curve takes the form of BMDβ=β(HUβ a)β+βb where a is the slope of the resulting calibration curve and b is the intercept. This calibration curve is applied to specific bone compartments in the image or to the entire image, creating a bone-equivalent density image. The values of a and bβ depend on many factors, such as the composition of the X-ray spectrum emitted by the X-ray tube, tube current, reconstruction kernel or table height, and as a result are scanner and image protocol dependent. To run phantom calibration in Ogo, you will need two things: <ol> <li>The raw CT scan (.nii or .nii.gz)</li> <li>A segmentation mask of the phantom rods</li> </ol> Typically, this is done using ITKSnap or some other automated method [TBD], and you segment the inside of the rods, making sure to stop before reaching the edge of the rod to avoid partial volume effects. An example of the phantom rods segmented: [[Image:phantom_rods_seg.png|600px]] [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ===Asynchronous calibration=== This also uses a phantom, but not at the same time as the scan of the patient. Sometimes it can be months or even years away. (This is an ongoing edited section...) [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']] ===Internal calibration=== This doesn't use a phantom, but instead uses the internal tissues as referents. [[Image:Redirect.jpg|15px]] [[#top|''Return to Contents'']] or [[Main_Page|''Return to Main Page'']]
Summary:
Please note that all contributions to bone.wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
BoneWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Log in
associated-pages
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main page
Documents
Recent changes
Help
Tools
What links here
Related changes
Page information